Our optical thin film coater is equipped with HOM2-RT-S1 to control the optical film thickness at high accuracy.
特長
Automatic coating can be controlled as accurately as 350nm to 2400nm for one measuring range.
Extremely low noize of ±0.001% achieved at wavelength resolution of 0.2nm or lower.
Automatically selectable measuring method (transmittance/ reflectance).

Specifications

Model HOM2-RT-S1
Wavelength range 350nm - 2400nm
Wavelength Resolution 0.2nm
Light Source Halogen lamp
Power Requirements AC100V±10%, 50/60Hz
 